Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.589
Filtrar
1.
Skin Res Technol ; 30(3): e13655, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481085

RESUMO

BACKGROUND: The stratum corneum (SC), the outermost layer of the skin epidermis, acts as an effective bi-directional barrier, preventing water loss (inside-outside barrier) and entry of foreign substances (outside-inside barrier). Although transepidermal water loss (TEWL) is a widely-used measure of barrier function, it represents only inside-outside protection. Therefore, we aimed to establish a non-invasive method for quantitative evaluation of the outside-inside barrier function and visually present a skin barrier model. MATERIALS AND METHODS: Skin barrier damage was induced by applying a closed patch of 1% sodium dodecyl sulfate to the forearms of eight participants; they were instructed to apply a barrier cream on a designated damaged area twice daily for 5 days. The SC barrier was evaluated by measuring TEWL and fluorescein sodium salt penetration rate before, immediately after, and 5 days after damage. The penetration rate was assessed using tape-stripping (TS) technique and fluorescence microscopy. RESULTS: The rates of fluorescein sodium salt penetration into the lower layers of SC differed significantly based on the degree of skin barrier damage. The correlation between penetration rate and TEWL was weak after two rounds of TS and became stronger after subsequent rounds. Five days after skin barrier damage, the penetration rate of all layers differed significantly between areas with and without the barrier cream application. CONCLUSION: Our findings demonstrated that the penetration rate was dependent on skin barrier conditions. The penetration rate and corresponding fluorescence images are suitable quantitative indicators that can visually represent skin barrier conditions.


Assuntos
Dermatopatias , Perda Insensível de Água , Humanos , Fluoresceína/metabolismo , Fluoresceína/farmacologia , Epiderme/metabolismo , Pele/metabolismo , Dermatopatias/metabolismo , Água/metabolismo , Emolientes/farmacologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-38452971

RESUMO

In terrestrial vertebrates, the outermost layer of the skin, the stratum corneum (SC), provides a durable and flexible interface with the environment and is comprised of corneocytes embedded in lipids. However, the morphology and lipid composition of the SC varies throughout evolutionary history. Because crocodilians and birds phylogenetically bracket the Archosaurian clade, lipid composition in crocodilian SC may be compared with that of birds and other vertebrates to make inferences about broader phylogenetic patterns within Archosaurs while highlighting adaptations in vertebrate skin. We identified and quantified lipid classes in the SC of the American Alligator (Alligator mississippiensis) from three skin regions varying in mobility. Our results find similarities in lipid composition between alligator and avian SC, including a high percentage of cerebrosides, a polar lipid previously found only in the SC of birds and bats. Furthermore, polar lipids were more abundant in the most mobile region of the SC. Because polar lipids bind with water to increase skin hydration and therefore its pliability under physical stress, we hypothesize that selection for lipids in Archosaurian SC was driven by the unique distribution of proteins in the SC of this clade, and cerebrosides may have served as pre-adaptations for flight.


Assuntos
Jacarés e Crocodilos , Quirópteros , Animais , Filogenia , Lipídeos , Perda Insensível de Água/fisiologia , Epiderme/metabolismo , Aves , Cerebrosídeos/metabolismo
3.
J Biol Rhythms ; 39(2): 208-214, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38305093

RESUMO

Atopic dermatitis (AD) is symptomatically worse in the evening, but the mechanism driving nocturnal eczema remains elusive. Our objective was to determine the circadian rhythm of skin barrier function measured by transepidermal water loss (TEWL) in AD patients and explore the molecular underpinnings. A pilot study was performed on a diverse group of AD (n = 4) and control (n = 2) young patients. We used an inpatient tightly controlled, modified, constant routine protocol. TEWL was measured at least every 90 min in the antecubital fossa (lesional) and forearm, while whole blood samples were collected every 4 h. Results show a significant difference in the antecubital fossa TEWL in the AD group versus controls. TEWL in control skin decreases starting a few hours prior to bedtime, both in the antecubital fossa and in the forearm, while in the AD forearm skin, pre-bedtime TEWL increases. We identified 1576 differentially expressed genes using a time-dependent model. The top 20 upregulated gene ontology pathways included neuronal pathways, while the downregulated functional terms included innate immune signaling and viral response. Similar pathways positively correlated with forearm TEWL in controls and inversely with the AD group. Upregulation in sensory perception pathways correlated with increases in lesional (antecubital fossa) TEWL in the evening. Results show skin barrier function worsens in the evening in the AD group, at a time when barrier is normally rejuvenating in healthy skin. This timing and the detection of transcriptomic signatures of sensory perception and diminished viral response might correspond to the nocturnal itch. Larger studies are needed to evaluate these associations in the skin.


Assuntos
Dermatite Atópica , Humanos , Dermatite Atópica/diagnóstico , Projetos Piloto , Perda Insensível de Água/fisiologia , Ritmo Circadiano , Pele
4.
Skin Res Technol ; 30(2): e13591, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38279544

RESUMO

PURPOSE: Electrical stimulation (ES) is a widely used technique in the medical field for various purposes. The effect of ES on several skin properties has been investigated; however, its effect on skin vulnerability to irritants remains unknown. This study aimed to investigate the effects of ES application on skin vulnerability to external irritants. MATERIALS AND METHODS: An experimental study on 12 healthy male subjects (Mean ± SD, 22.9 ± 3.6 years) who completed the study. The subjects were free of skin abnormalities in the volar aspect of both forearms. Three areas were allocated to each forearm and marked as areas 1, 2, and A in the treated forearm, and areas 3, 4, and B in the control forearm. ES was applied to the volar aspect of the treated forearm for 30 min three times a week, for 2 weeks. The effect of ES on skin vulnerability was investigated using 5% and 0.5% sodium lauryl sulfate (SLS) patches applied to both treated and control forearms. The skin response to irritants was evaluated using transepidermal water loss (TEWL) and a visual erythema score 24 h after patch removal. RESULTS: Compared to the control forearm, ES increased skin permeability and erythema in response to external irritants (SLS), as measured by the visual analog score (Z = 2.75, p = 0.006) and TEWL (p < 0.05), respectively. CONCLUSIONS: ES escalates skin reactions to low concentrations of irritant substances, such as SLS, in the area between the two electrodes. This emphasizes the use of this substance, and similar irritants should be avoided in areas treated with ES.


Assuntos
Dermatite Irritante , Irritantes , Masculino , Humanos , Irritantes/farmacologia , Dermatite Irritante/etiologia , Perda Insensível de Água , Pele , Dodecilsulfato de Sódio/farmacologia , Eritema
5.
Int J Cosmet Sci ; 46(1): 85-95, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37699769

RESUMO

OBJECTIVE: This study aimed to assess the effect of 1,3-propanediol at different concentrations (5%, 10%, or 15%), either applied alone or in combination with butylene glycol (BG) (5%) and/or glycerol (5%), on skin hydration and skin barrier function. The measurements were conducted using capacitance to determine skin hydration and trans epidermal water loss (TEWL) rates to evaluate skin barrier function. METHODS: A total of 30 healthy female subjects participated in the study. Capacitance and TEWL measurements were conducted at multiple time points, including before application and at 15 min, 2 and 8 h after the humectants were applied to the forearms of the subjects. All the subjects provided written informed consent. RESULTS: The 1,3-propanediol in all concentrations and in all combinations (with BG and/or glycerol) increased skin hydration and improved skin barrier function 15 min, 2 and 8 h after application. Glycerol increased the hydration performance of 1,3-propanediol. The application of 1,3-propanediol at a concentration of 15%, either alone or in combination with other humectants, reduced the TEWL to a greater extent than lower concentrations of 1,3-propanediol. Furthermore, the addition of glycerol to 1,3-propanediol 15% improved the skin barrier and reduced TEWL when compared with 1,3-propanediol alone and with the combination of 1,3-propanediol + BG. CONCLUSION: The humectants significantly improved skin hydration and reduced TEWL throughout the 8-h time course. The increase in 1,3-propanediol concentration, as well as its combination with glycerol, provided a greater benefit to the skin, improving both hydration and the skin barrier function.


OBJECTIF: Cette étude visait à évaluer l'effet sur l'hydratation de la peau et la fonction de barrière cutanée du 1,3-propanediol à différentes concentrations (5 %, 10 % ou 15 %), appliqué seul ou en association avec du butylène glycol (5 %) et/ou du glycérol (5 %). Les mesures ont été effectuées à l'aide de la capacitance pour déterminer l'hydratation de la peau et les taux de perte d'eau transépidermique (Trans Epidermal Water Loss, TEWL) pour évaluer la fonction de barrière cutanée. MÉTHODES: Au total, 30 sujets de sexe féminin en bonne santé ont participé à l'étude. Les mesures de la capacitance et de la TEWL ont été effectuées à plusieurs moments, y compris avant l'application, 15 minutes, 2 heures et 8 heures après l'application des produits humectant sur les avant-bras des sujets. Tous les sujets ont fourni un consentement éclairé écrit. RÉSULTATS: Le 1,3-propanediol, à toutes les concentrations et dans toutes les associations (avec le butylène glycol et/ou le glycérol), a augmenté l'hydratation de la peau et amélioré la fonction de barrière cutanée à 15 minutes, 2 heures et 8 heures après l'application. Le glycérol a augmenté les performances d'hydratation du 1,3-propanediol. L'application de 1,3-propanediol à une concentration de 15 %, seul ou en association avec d'autres produits humectant, a réduit la TEWL dans une plus grande mesure que des concentrations inférieures de 1,3-propanediol. En outre, l'ajout de glycérol au 1,3-propanediol 15 % a amélioré la barrière cutanée et réduit la TEWL par rapport au 1,3-propanediol seul et à l'association 1,3-propanediol + butylène glycol. CONCLUSION: Les produits humectant ont significativement amélioré l'hydratation de la peau et réduit la TEWL tout au long des 8 heures. L'augmentation de la concentration de 1,3-propanediol, ainsi que son association avec le glycérol, ont apporté un plus grand bénéfice à la peau, améliorant à la fois l'hydratation et la fonction de barrière cutanée.


Assuntos
Glicerol , Higroscópicos , Propilenoglicóis , Feminino , Humanos , Glicerol/farmacologia , Glicerol/metabolismo , Higroscópicos/farmacologia , Pele , Água/metabolismo , Propilenoglicol/farmacologia , Propilenoglicol/metabolismo , Butileno Glicóis/metabolismo , Butileno Glicóis/farmacologia , Perda Insensível de Água
6.
J Exp Biol ; 227(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38073475

RESUMO

Changes in environmental temperature during development can affect growth, metabolism and temperature tolerance of the offspring. We know little about whether such changes remain to adulthood, which is important to understand the links between climate change, development and fitness. We investigated whether phenotypic consequences of the thermal environment in early life remained in adulthood in two studies on Japanese quail (Coturnix japonica). Birds were raised under simulated heatwave, cold snap or control conditions, from hatching until halfway through the growth period, and then in common garden conditions until reproductively mature. We measured biometric and thermoregulatory [metabolic heat production (MHP), evaporative water and heat loss (EWL, EHL) and body temperature] responses to variation in submaximal air temperature at the end of the thermal acclimation period and in adulthood. Warm birds had lower MHP than control birds at the end of the thermal acclimation period and, in the warmest temperature studied (40°C), also had higher evaporative cooling capacity compared with controls. No analogous responses were recorded in cold birds, although they had higher EWL than controls in all but the highest test temperature. None of the effects found at the end of the heatwave or cold snap period remained until adulthood. This implies that chicks exposed to higher temperatures could be more prepared to counter heat stress as juveniles but that they do not enjoy any advantages of such developmental conditions when facing high temperatures as adults. Conversely, cold temperature does not seem to confer any priming effects in adolescence.


Assuntos
Temperatura Corporal , Coturnix , Humanos , Animais , Adolescente , Adulto , Temperatura Corporal/fisiologia , Temperatura Baixa , Temperatura Alta , Perda Insensível de Água/fisiologia , Regulação da Temperatura Corporal/fisiologia
7.
ACS Sens ; 8(11): 4407-4416, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37953512

RESUMO

Early diagnosis of skin barrier dysfunction helps provide timely preventive care against diseases such as atopic dermatitis, psoriasis, food allergies, and other atopic skin disorders. Skin barrier function is commonly evaluated by measuring the transepidermal water loss (TEWL) through stratum corneum due to its noninvasive characteristics. However, existing commercial TEWL devices are significantly affected by many factors, such as ambient temperature, humidity, air flow, water accumulation, initial water contents on the skin surface, bulky sizes, high costs, and requirements for well-controlled environments. Here, we developed a wearable closed-chamber hygrometer-based TEWL device (Wearable Analytical Skin Probe, WASP) and the related algorithm for accurate and continuous monitoring of skin water vapor flux. The WASP uses short dry air purges to dry the skin surface and chamber before each water vapor flux measurement. Its design ensures a highly controlled local environment, such as consistent initial dry conditions for the skin surface and the chamber. We further applied WASP to measure the water vapor flux from six different locations of a small group of human participants. It is found that the WASP can not only measure and distinguish between insensible sweating (i.e., TEWL) and sensible sweating (i.e., thermal sweating) but also track skin dehydration-rehydration cycles. Comparisons with a commercial TEWL device, AquaFlux, show that the results obtained by both devices agree well. The WASP will be broadly applicable to clinical, cosmetic, and biomedical research.


Assuntos
Vapor , Perda Insensível de Água , Humanos , Pele , Epiderme , Umidade
8.
Skin Pharmacol Physiol ; 36(4): 174-185, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37717558

RESUMO

BACKGROUND: The anatomic layers of the skin are well-defined, and a functional model of the skin barrier has recently been described. Barrier disruption plays a key role in several skin conditions, and moisturization is recommended as an initial treatment in conditions such as atopic dermatitis. This review aimed to analyze the skin barrier in the context of the function model, with a focus on the mechanisms by which moisturizers support each of the functional layers of the skin barrier to promote homeostasis and repair. SUMMARY: The skin barrier is comprised of four interdependent layers - physical, chemical, microbiologic, and immunologic - which maintain barrier structure and function. Moisturizers target disruption affecting each of these four layers through several mechanisms and were shown to improve transepidermal water loss in several studies. Occlusives, humectants, and emollients occlude the surface of the stratum corneum (SC), draw water from the dermis into the epidermis, and assimilate into the SC, respectively, in order to strengthen the physical skin barrier. Acidic moisturizers bolster the chemical skin barrier by supporting optimal enzymatic function, increasing ceramide production, and facilitating ideal conditions for commensal microorganisms. Regular moisturization may strengthen the immunologic skin barrier by reducing permeability and subsequent allergen penetration and sensitization. KEY MESSAGES: The physical, chemical, microbiologic, and immunologic layers of the skin barrier are each uniquely impacted in states of skin barrier disruption. Moisturizers target each of the layers of the skin barrier to maintain homeostasis and facilitate repair.


Assuntos
Dermatite Atópica , Pele , Humanos , Pele/metabolismo , Dermatite Atópica/tratamento farmacológico , Dermatite Atópica/metabolismo , Epiderme , Emolientes/metabolismo , Água/metabolismo , Perda Insensível de Água
9.
Skin Pharmacol Physiol ; 36(4): 165-173, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37640014

RESUMO

BACKGROUND: Obesity is a condition defined by an excess amount of body fat, with body mass index (BMI) of 30 and higher. It is associated with a number of other medical conditions, including insulin resistance, diabetes mellitus, and cardiovascular diseases, as well as dyslipidemia, and it is also associated with several cutaneous disorders such as atopic dermatitis, psoriasis, intertriginous dermatitis, acanthosis nigricans and skin infections. SUMMARY: Evidence suggests a link between obesity and epidermal dysfunction. Generally, individuals with obesity display higher transepidermal water loss rate and lower stratum corneum hydration levels, although no association of obesity with epidermal dysfunction has been documented. Results of skin surface pH are controversial. But study demonstrated a positive correlation of BMI with skin surface pH on both the forearm and the shin in males, suggesting that the changes in epidermal function vary with gender in individuals with obesity. KEY MESSAGES: This review summarizes the association between obesity and epidermal function, and discusses possible underlying mechanisms. Individuals with obesity exhibit poor epidermal permeability barrier and lower stratum corneum hydration levels. Because of the pathogenic role of compromised epidermal function in inflammation, which is also linked to obesity, improvement in epidermal function could benefit individuals with obesity, particularly those with abnormalities in epidermal function.


Assuntos
Dermatite Atópica , Dermatopatias , Masculino , Humanos , Epiderme/metabolismo , Pele/patologia , Dermatopatias/patologia , Administração Cutânea , Dermatite Atópica/metabolismo , Perda Insensível de Água
10.
Int J Obes (Lond) ; 47(10): 963-969, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37479793

RESUMO

BACKGROUND: Skin diseases impact significantly on the quality of life and psychology of patients. Obesity has been observed as a risk factor for skin diseases. Skin epidermal barrier dysfunctions are typical manifestations across several dermatological disturbances. OBJECTIVES: We aim to establish the association between obesity and skin physiology measurements and investigate whether obesity may play a possible causal role on skin barrier dysfunction. METHODS: We investigated the relationship of obesity with skin physiology measurements, namely transepidermal water loss (TEWL), skin surface moisture and skin pH in an Asian population cohort (n = 9990). To assess for a possible causal association between body mass index (BMI) and skin physiology measurements, we performed Mendelian Randomization (MR), along with subsequent additional analyses to assess the potential causal impact of known socioeconomic and comorbidities of obesity on TEWL. RESULTS: Every 1 kg/m2 increase in BMI was associated with a 0.221% (95%CI: 0.144-0.298) increase in TEWL (P = 2.82E-08), a 0.336% (95%CI: 0.148-0.524) decrease in skin moisture (P = 4.66E-04) and a 0.184% (95%CI: 0.144-0.224) decrease in pH (P = 1.36E-19), adjusting for age, gender, and ethnicity. Relationships for both TEWL and pH with BMI remained strong (Beta 0.354; 95%CI: 0.189-0.520 and Beta -0.170; 95%CI: -0.253 to -0.087, respectively) even after adjusting for known confounders, with MR experiments further supporting BMI's possible causal relationship with TEWL. Based on additional MR performed, none of the socioeconomic and comorbidities of obesity investigated are likely to have possible causal relationships with TEWL. CONCLUSION: We establish strong association of BMI with TEWL and skin pH, with MR results suggestive of a possible causal relationship of obesity with TEWL. It emphasizes the potential impact of obesity on skin barrier function and therefore opportunity for primary prevention.


Assuntos
Obesidade , Fenômenos Fisiológicos da Pele , Perda Insensível de Água , Humanos , Causalidade , Obesidade/complicações , Obesidade/epidemiologia , Fatores de Risco , Povo Asiático
11.
Skin Res Technol ; 29(6): e13397, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37357654

RESUMO

BACKGROUND: In Korea, winter can cause skin dryness due to low relative humidity (RH); moreover, indoor heating devices promote moisture loss and air pollution. If dryness persists, dead skin cells accumulate, leading to skin problems; therefore, careful skin care is required. This study aimed to compare changes in skin conditions when exposed to an indoor environment for a short period of 6 h in winter, and to suggest proper winter skin care practices. METHODS: A randomized, split-face clinical study was conducted in which healthy female participants with normal skin were exposed to an indoor environment with a heater turned on for a short period at least 6 h per day in the winter season, and cream was applied to one side of the face. Skin temperature, hydration, sebum, transepidermal water loss (TEWL), elasticity, texture, pores, redness, and wrinkles were measured at the treated and nontreated sites. RESULTS: After 6 h of exposure, skin temperature, pores, roughness, redness, and wrinkles significantly increased (p < 0.05) on the face, whereas TEWL significantly increased on the forearm (p < 0.05). However, sebum secretion appeared to function as a barrier to maintain homeostasis in the facial skin. Elasticity, pores, texture, and wrinkles in the cream-treated ceramide site improved compared to those in the nontreated site (p < 0.05). The moisture content was also significantly higher in the forearm (p < 0.05). CONCLUSION: Changes in skin parameters of participants with healthy skin were observed even after short-term exposure to an indoor environment in winter. Creams containing ceramide maintain skin homeostasis and protect the skin barrier; therefore, it is recommended to use such creams to prevent skin damage and maintain healthy skin, particularly during prolonged exposure to indoor environments during winter.


Assuntos
Exposição Ambiental , Envelhecimento da Pele , Temperatura Cutânea , Pele , Humanos , Perda Insensível de Água , Exposição Ambiental/efeitos adversos , República da Coreia , Estações do Ano
12.
Exp Dermatol ; 32(9): 1420-1429, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37302006

RESUMO

Infant and adult skin physiology differ in many ways; however, limited data exist for older children. To further investigate the maturation processes of healthy skin during childhood. Skin parameters were recorded in 80 participants of four age groups: babies (0-2 years), young children (3-6 years), older children (7-<10 years) and adults (25-40 years). Overall, skin barrier function continues to mature, reaching adult levels of transepidermal water loss (TEWL), lipid compactness, stratum corneum (SC) thickness and corneocyte size by the age of about 6 years. Higher levels of lactic acid and lower levels of total amino acids in the SC of babies and young children further indicate higher cell turnover rates. In all age groups, TEWL and skin surface hydration values remain higher on the face compared with the arm. Skin becomes darker and contains higher levels of melanin with increasing age. The composition of skin microbiome of the dorsal forearm in all children groups is distinct from that in adults, with Firmicutes predominating in the former and Proteobacteria in the latter. Skin physiology, along with the skin microbiome, continues to mature during early childhood in a site-specific manner.


Assuntos
Pele , Perda Insensível de Água , Adulto , Criança , Lactente , Humanos , Pré-Escolar , Adolescente , Recém-Nascido , Pele/metabolismo , Epiderme/metabolismo , Fenômenos Fisiológicos da Pele , Água/metabolismo
13.
Skin Res Technol ; 29(5): e13346, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37231932

RESUMO

INTRODUCTION: The fundamental function of the epidermis is to provide an inside-out barrier to water loss and an outside-in barrier to penetration of external irritants. Transepidermal water loss (TEWL) has been extensively used as a method of estimating the skin barrier quality, typically without any consideration of directionality. The validity of TEWL as an estimate of skin permeability to external substances has been controversial in vitro and in vivo. The aim of this work was to assess the relationship between TEWL and the penetration of a topically applied external marker (caffeine) in healthy skin in vivo before and following a challenge to the barrier. METHODS: The skin barrier was challenged by application of aqueous solutions of mild cleanser products under occlusion for 3 h on the forearms of nine human participants. Skin barrier quality was evaluated before and after the challenge by measuring the TEWL rate and the permeated amount of topically applied caffeine using in vivo confocal Raman microspectroscopy. RESULTS: No skin irritation was observed following the skin barrier challenge. TEWL rates and the caffeine penetrated amount in the stratum corneum after the challenge were not correlated. A weak correlation was observed when the changes were corrected to water-only treatment. TEWL values can be influenced by environmental conditions as well as the skin temperature and water content. CONCLUSIONS: Measuring TEWL rates is not always representative of the outside-in barrier. TEWL may be useful in differentiating large changes in skin barrier function (e.g., between healthy and compromised skin) but is less sensitive to small variations following topical application of mild cleansers.


Assuntos
Cafeína , Água , Humanos , Cafeína/farmacologia , Cafeína/metabolismo , Água/metabolismo , Temperatura Cutânea , Epiderme/metabolismo , Células Epidérmicas , Perda Insensível de Água
14.
Int J Pharm ; 638: 122930, 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37028576

RESUMO

Trans-epidermal water loss (TEWL) has been the most widely used method to assess the integrity of the skin barrier and evaluate the irritation potential or the protective properties of topical products for many years. It detects the amount of water that diffuses across the stratum corneum (SC) to the external environment. As one of the most important functions of the skin is to keep water inside the body, an increase in TEWL is used to indicate the skin's impaired barrier function. So far, a variety of commercial instruments are available to measure the TEWL. Their applications mainly focus on the in-vivo TEWL measurements for dermatological examinations or formulation development. Recently, an in-vitro TEWL probe has also been commercially released enabling preliminary tests with excised skin samples. In our study, we first aimed to optimize the experimental procedures for detecting the in-vitro TEWL of porcine skin. Secondly, different kinds of emulsifiers were applied to the skin, including polyethylene glycol-containing emulsifiers (PEG-ylated emulsifiers), sorbitan esters, cholesterol, and lecithin. Sodium lauryl sulfate (SLS) was used as a positive control, and water as a negative control. Based on the findings, we established a protocol for accurately measuring the in-vitro TEWL values, emphasizing that the temperature of the skin sample should be constantly maintained at 32℃. Subsequently, the influences of emulsifiers on the in-vitro TEWL were analyzed. They indicated a significant skin barrier impairment of PEG-20 cetyl ether, PEG-20 stearyl ether, and SLS on in-vitro skin. Furthermore, we interestingly found that there consistently was an alteration of the TEWL values, even after the application of water to the skin. Our findings are of special interest, as the European Medicines Agency (EMA) recommends the use of in-vitro TEWL to determine skin barrier intactness during Franz cell experiments. Thus, this study provides a validated protocol for measuring the in-vitro TEWL and elucidates the impact of emulsifiers on the skin barrier. It also improves the understanding of tolerable variations of in-vitro TEWL and offers recommendations for its use in research.


Assuntos
Pele , Água , Água/metabolismo , Pele/metabolismo , Epiderme , Dodecilsulfato de Sódio/metabolismo , Emulsificantes/metabolismo , Perda Insensível de Água
15.
Contact Dermatitis ; 89(1): 26-36, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37015218

RESUMO

BACKGROUND: Semipermeable membranes might be suitable for glove liners or comfort gloves in individuals with irritant contact dermatitis (ICD). OBJECTIVES: To evaluate the effects of different glove materials on inflammation and epidermal barrier impairment after experimental skin irritation. METHODS: Nine test areas on the volar forearms of 24 healthy volunteers were irritated with sodium lauryl sulfate (1%) and afterward covered for 6 days (6 or 8 h/day) with semipermeable Sympatex (SYM), vinyl (OCC), combinations of vinyl with Sympatex (SYM/OCC) or cotton (COT/OCC), or left uncovered (CON). Up to day 10, measurements of transepidermal water loss (TEWL), erythema (a*), skin humidity (SH) and visual scoring (VS) were applied. RESULTS: No significant differences in skin parameters were found between COT/OCC and SYM/OCC as well as between each of the combinations and CON. SYM, COT/OCC and SYM/OCC led to better results for most skin parameters than OCC alone. CONCLUSIONS: Occlusive material has a negative impact on skin barrier recovery and inflammation after skin irritation whereas SYM is not inferior to uncovered areas indicating good tolerability. Altogether, the data suggest that SYM is a useful alternative to COT as material for glove liners and comfort gloves in ICD patients.


Assuntos
Dermatite Alérgica de Contato , Dermatite Irritante , Humanos , Dermatite Alérgica de Contato/metabolismo , Perda Insensível de Água , Pele/metabolismo , Epiderme , Dermatite Irritante/etiologia , Dermatite Irritante/prevenção & controle , Dermatite Irritante/metabolismo , Inflamação/metabolismo , Dodecilsulfato de Sódio/efeitos adversos
16.
Skin Res Technol ; 29(4): e13307, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37113085

RESUMO

BACKGROUND: Instrumentation technology for transepidermal water loss measurements has not been substantially modified since its introduction by Nilsson in 1977. Recent progress in sensor development allowed a new sensor arrangement using a matrix of 30 sensors. Raw measurement values are processed with spatial statistical analysis. We aimed to compare the new, multi-sensor probe (Tewameter TM Hex) with the established Tewameter TM 300 probe and to gain reference data for the new parameters of transepidermal energy loss and water vapor concentration on skin. MATERIAL AND METHODS: Baseline measurements and repeated measurements on the volar forearm and assessment on eight different anatomical locations were performed on 24 healthy volunteers (both gender) with the TM Hex and the TM 300. RESULTS: A significant correlation (p < 0.001; R-coefficient = 0.9) between TM Hex and the TM 300 with a low coefficient of variance (CV) 11% for TM Hex and 19% for TM 300, could be assessed. The CV ranged between 7% (right inner upper arm) and 14% (palms). Average transepidermal heat loss ranged from 12 W/m2 on the lower leg to 38.8 W/m2 on the palm. CONCLUSION: The correlation between TM Hex and TM 300 along with the robustness of the measurements with the TM Hex shows that the new probe for assessment of epidermal barrier function is comparable to the TM 300. In most conditions, TM Hex provides more accurate measurements than TM 300. New parameters open the field to studying skin's water and energy balance.


Assuntos
Epiderme , Pele , Humanos , Epiderme/diagnóstico por imagem , Antebraço , Mãos , Perna (Membro) , Perda Insensível de Água
17.
Sensors (Basel) ; 23(8)2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37112275

RESUMO

Atopic dermatitis (AD) is one of the most common skin disorders, affecting nearly one-fifth of children and adolescents worldwide, and currently, the only method of monitoring the condition is through an in-person visual examination by a clinician. This method of assessment poses an inherent risk of subjectivity and can be restrictive to patients who do not have access to or cannot visit hospitals. Advances in digital sensing technologies can serve as a foundation for the development of a new generation of e-health devices that provide accurate and empirical evaluation of the condition to patients worldwide. The goal of this review is to study the past, present, and future of AD monitoring. First, current medical practices such as biopsy, tape stripping and blood serum are discussed with their merits and demerits. Then, alternative digital methods of medical evaluation are highlighted with the focus on non-invasive monitoring using biomarkers of AD-TEWL, skin permittivity, elasticity, and pruritus. Finally, possible future technologies are showcased such as radio frequency reflectometry and optical spectroscopy along with a short discussion to provoke research into improving the current techniques and employing the new ones to develop an AD monitoring device, which could eventually facilitate medical diagnosis.


Assuntos
Dermatite Atópica , Criança , Adolescente , Humanos , Dermatite Atópica/diagnóstico , Perda Insensível de Água , Pele/patologia , Prurido/patologia , Biomarcadores
18.
J Eur Acad Dermatol Venereol ; 37(7): 1284-1292, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36995919

RESUMO

Skin barrier dysfunction plays an important role in atopic dermatitis (AD) aetiopathogenesis. Dupilumab, a drug that inhibits IL-4 and IL-13, is an effective treatment for AD but there is scarce evidence about its impact on epidermal barrier. The objective of this systematic review is to evaluate the influence of dupilumab on skin barrier in patients with AD using non-invasive tools. A systematic review was designed following PRISMA guidelines. The literature search identified 73 references and, finally, only 6 were selected, including a total of 233 participants. All the studies were prospective observational studies. Dupilumab improved clinical scores in all the research. Skin barrier function parameters were mainly measured on the volar forearm. Transepidermal water loss (TEWL) was the parameter most frequently measured, evaluated in all the studies. Dupilumab decreased TEWL on eczematous lesions and non-involved skin. About 33.6% (2/6) studies reported that dupilumab also increased stratum corneum hydration (SCH) on eczematous lesions while one study did not report any changes in this parameter. This drug also decreased temperature and improved ceramide composition. In conclusion, dupilumab improved skin barrier function in AD patients, mainly reflected in a decreased in TEWL values.


Assuntos
Dermatite Atópica , Perda Insensível de Água , Humanos , Pele/patologia , Dermatite Atópica/tratamento farmacológico , Epiderme , Estudos Observacionais como Assunto
19.
Skin Res Technol ; 29(3): e13297, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36973975

RESUMO

BACKGROUND: Although it is known that epidermal biophysical properties vary with age and gender, the changes in epidermal biophysical properties over the time from baby to adolescence have not been elucidated yet. In the present study, we assessed the trend of changes in transepidermal water loss rates (TEWL), stratum corneum hydration, and skin surface pH in Chinese children. PARTICIPANTS AND METHODS: A total of 780 boys and 610 girls, aged 1 month to 17-year old, were enrolled in this study. TEWL and stratum corneum hydration on the forearm and the shin were measured with GPSkin Barrier, whereas skin surface pH was measured with portable skin pH meter. RESULTS: Overall, TEWL and stratum corneum hydration levels decreased, whereas skin surface pH increased in children from 1-month old to 17-year old. Significant decline in TEWL was observed on both the forearm and the shin of girls, and the shin of boys aged 13-17-year old. Similarly, marked decline in stratum corneum hydration levels started at ages of 6-12-year old. In contrast, decline in skin surface pH was observed in both girls and boys aged one to 12-month old except on the forearm of boys. Afterward, skin surface pH remained either stable or slight increase except on the shin of boys aged >12 months to 3-year old. CONCLUSIONS: These results demonstrate that both TEWL and stratum corneum hydration levels decrease, whereas skin surface pH increases in children aged 1 month to 17-year old. The changes in these biophysical properties vary with age, gender, and body site.


Assuntos
População do Leste Asiático , Epiderme , Adolescente , Criança , Feminino , Humanos , Lactente , Masculino , Povo Asiático , Epiderme/metabolismo , Antebraço , Pele/metabolismo , Perda Insensível de Água , Pré-Escolar
20.
Skin Res Technol ; 29(3): e13218, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36973986

RESUMO

BACKGROUND: Skin measurements of transepidermal water loss (TEWL) and stratum corneum hydration (SCH) reflect different aspects of skin physiology. Since epidermal water loss depends on epidermal-to-air water vapor gradients, a possible quantitative relationship between TEWL and SCH may exist. This investigation's purpose was to test the possible TEWL-SCH relationship. MATERIALS AND METHODS: SCH and TEWL were measured noninvasively on forearm and palmer thenar eminence (hand) in 40 young adults (20 males) along with total body fat percentage (FAT) via bioimpedance. RESULTS: A significant positive nonlinear correlation (p < 0.001) was detected between SCH and TEWL in hands of the male cohort that occurred when SCH exceeded a threshold level. This threshold level was not exceeded in male or female forearms and forearms did not display a SCH-TEWL correlation. There was a weak inverse dependence of TEWL on FAT on both forearm and hand (p < 0.05), but no SCH-FAT relationship was observed. TEWL values on the forearm and hand were moderately correlated with each other (p = 0.002) but SCH values were not. CONCLUSION: The findings clarify the relationship between forearm and palmer hydration and TEWL values, and their relationship to total body fat percentages in young healthy adults. The significant correlation between palmer stratum corneum hydration and palmer TEWL that was discovered in the male but not the female cohort suggests a threshold hydration level for which TEWL depends both on skin barrier function and stratum corneum hydration. This implies that conditions with increased SCH may in part account for elevated TEWL values.


Assuntos
Epiderme , Antebraço , Mãos , Perda Insensível de Água , Feminino , Humanos , Masculino , Adulto Jovem , Epiderme/química , Epiderme/metabolismo , Epiderme/fisiologia , Antebraço/fisiologia , Mãos/fisiologia , Pele/química , Pele/metabolismo , Fenômenos Fisiológicos da Pele , Perda Insensível de Água/fisiologia , Vapor/análise , Estado de Hidratação do Organismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...